RGO DosimetryThermoluminescent dosimetry products

TLD elements and wearable dosimeters

Reliable consumables for professional radiation monitoring workflows.

RGO Dosimetry supplies reusable TLD elements, badge dosimeters and extremity dosimeter configurations for qualified laboratories, radiation monitoring service providers and specialist distributors.

  • LiF material options
  • Wearable holder formats
  • Sample and batch enquiries
Beijing RGO Instrument Ltd. International sample enquiries Material selection support Batch evaluation discussions

What buyers need

Built around the decisions a dosimetry buyer has to make.

Professional buyers are not only choosing a model number. They need material compatibility, application fit, repeatable supply and a clear path for laboratory validation.

01

Material matching

Choose LiF:Mg,Ti, LiF:Mg,Cu,P, energy-response optimised or lithium isotope material options based on radiation type, sensitivity and reader workflow.

02

Workflow integration

Use loose TLD elements for laboratory systems, or badge, ring and wrist formats for personal and extremity monitoring programmes.

03

Practical procurement

Start with samples, confirm dimensions and packaging, then move toward repeat purchasing after incoming inspection and calibration checks.

Product range

TLD products for laboratory evaluation and monitoring services.

Product suitability, calibration and dose interpretation should be verified by your qualified dosimetry laboratory before operational use.

RGO-TLD100 LiF:Mg,Ti TLD elementsTLD100

TLD elements

RGO-TLD100

Reusable LiF:Mg,Ti thermoluminescent dosimeter elements for professional radiation monitoring and laboratory evaluation.

  • LiF:Mg,Ti material
  • General-purpose element option
  • Sample enquiries welcome
Ask about TLD100
RGO-TLD1000 LiF:Mg,Cu,P TLD elementsTLD1000

High-sensitivity elements

RGO-TLD1000

Reusable LiF:Mg,Cu,P thermoluminescent dosimeter elements for professional dosimetry applications.

  • LiF:Mg,Cu,P material
  • High-sensitivity option
  • Configuration details on request
Ask about TLD1000
RGO-TLD1000E LiF:Mg,Cu,P(E) TLD elementsTLD1000E

Energy-response optimised

RGO-TLD1000E

Reusable LiF:Mg,Cu,P(E) thermoluminescent dosimeter elements for professional dosimetry applications.

  • LiF:Mg,Cu,P(E) material
  • Round element format
  • Technical details on request
Ask about TLD1000E
RGO-TLD6000 6LiF:Mg,Cu,P TLD elementsTLD6000

Neutron workflow option

RGO-TLD6000

Reusable 6LiF:Mg,Cu,P thermoluminescent dosimeter elements for selected neutron and gamma mixed-field workflows.

  • 6LiF:Mg,Cu,P material
  • Round element format
  • Laboratory evaluation required
Ask about TLD6000

Wearable dosimeters

Dosimeter holders for personal and extremity monitoring.

Choose wearable configurations based on placement, radiation field, element count, filter design and the monitoring protocol used by your laboratory.

RGO-J2000 ring TLD dosimeterJ2000

Ring dosimeter

RGO-J2000

A compact ring-style TLD dosimeter for hand exposure monitoring applications.

  • Extremity monitoring
  • X-ray, gamma and beta applications
  • Simple detector placement
Ask about J2000
RGO-J3000 badge TLD dosimeterJ3000

Badge dosimeter

RGO-J3000

A sealed wearable TLD badge for trunk dose monitoring and photon energy discrimination workflows.

  • Wearable badge format
  • Four-element configuration
  • Moisture-resistant housing
Ask about J3000
RGO-J4000E multi-function badge TLD dosimeterJ4000E

Multi-function badge

RGO-J4000E

A multi-element wearable TLD badge for personal radiation monitoring applications.

  • Multi-element configuration
  • Badge-style format
  • Technical details on request
Ask about J4000E
RGO-J5000 wrist TLD dosimeterJ5000

Wrist dosimeter

RGO-J5000

A wrist-worn TLD dosimeter with a tissue-equivalent plastic housing for extremity monitoring.

  • Comfortable wrist format
  • Moisture-resistant housing
  • Professional monitoring workflows
Ask about J5000

Selection guide

Help buyers move from application to model family.

The fastest path to a useful enquiry is to identify the monitoring workflow first, then match material, format and validation requirements.

Buyer need Recommended product family Qualification question
General photon personal monitoring RGO-TLD100 or RGO-J3000 Which reader, annealing cycle and holder design will be used?
Higher-sensitivity element evaluation RGO-TLD1000 or RGO-TLD1000E What dose range, repeatability target and fading test will be applied?
Mixed neutron/gamma workflow RGO-TLD6000 with laboratory validation Which radiation field and paired material method will be used?
Hand or extremity monitoring RGO-J2000 or RGO-J5000 Is finger, wrist or task-specific placement required?

Quality discussion

Positioned for evaluation, not blind substitution.

Professional dosimetry buyers expect batch evidence, incoming inspection and reader compatibility checks. RGO supports those conversations from the first sample enquiry.

01

Define the application

Clarify radiation type, dose range, monitoring position and required element or holder format.

02

Confirm configuration

Discuss dimensions, material, packaging, element count and sample quantity before ordering.

03

Evaluate incoming batch

Run repeatability, uniformity, background, fading and reader compatibility checks in your laboratory.

04

Scale procurement

Move to repeat purchasing only after your workflow confirms performance and calibration suitability.

Applications

Designed for professional radiation monitoring buyers.

Dosimetry laboratories

Reusable TLD elements for incoming inspection, calibration workflow evaluation and service programme integration.

Personal monitoring services

Badge, ring and wrist configurations for selected whole-body and extremity monitoring applications.

Research and industry

Practical TLD formats for nuclear, medical, industrial and academic radiation monitoring workflows.

Technical articles

Practical guidance for TLD evaluation

Short technical notes for laboratories, radiation monitoring organisations and distributors evaluating thermoluminescent dosimeter elements.

Selection guide

How to choose TLD elements for radiation monitoring

Start with radiation type, dose range, energy response, sensitivity and the complete dosimetry system rather than a material name alone.

Read article

Quality evaluation

How to evaluate the quality of TLD elements manufactured in China

Country of origin is not a performance specification. Use documented batch tests, traceable calibration and application-specific validation.

Read article

Laboratory workflow

A practical acceptance test for a new batch of TLD elements

A staged incoming-inspection workflow for laboratories assessing repeatability, background, fading and reader compatibility.

Read article

Start with a technical enquiry

Tell us your material, format and validation requirements.

Share your country, application, reader workflow, preferred product and estimated quantity. We will respond with available product information and sample options.

Contact on WhatsApp

Email: sales@rgodosimetry.com