A request for a “TLD badge” can mean an empty holder, a detector card, or a complete wearable assembly. Separating these components makes quotations easier to compare and helps laboratories select the correct readout workflow.
1. Detector elements: the sensing material
The detector element is the radiation-sensitive part. It may be supplied as a chip, disc or another specified format. A bare element is not a complete wearable dosimeter: the mounting, protective housing and readout method must also be defined.
When ordering TLD elements, specify the material, dimensions, quantity and intended reader. A matching material name alone does not establish system compatibility.
2. Detector cards: elements mounted in a defined layout
A detector card carries elements in fixed positions for handling and readout. The number of installed elements and their materials form part of the configuration. An empty card or adapter should be distinguished from a card supplied with detectors installed.
Our sealed TLD card range includes two-, three- and four-element configurations. Specify the exact card and holder combination when requesting a complete set.
3. Badge holders: the wearable housing
The badge holder houses the detector card during monitoring. Its filter arrangement is part of the dosimetry configuration. An empty holder does not measure dose on its own, and a similar external shape does not establish equivalent performance.
Ask whether a quoted price covers the holder only, the loaded detector card only, or both. For neutron monitoring, confirm the detector materials, filter arrangement and laboratory evaluation method together.
4. Reader carriers: adapters used during readout
A reader carrier positions a detector for processing in a specified reader. It serves a different purpose from a wearable badge holder. In our finger-ring workflow, the detector is placed directly into the ring and secured with its cap for use; for readout, it is removed and placed in the matching carrier.
For finger and wrist dosimeters, confirm whether detectors, caps and reader carriers are included or quoted separately.
5. TLD readers: laboratory processing equipment
The reader heats the detector and measures its emitted light. Converting that response into a reported dose requires the appropriate calibration and evaluation workflow. Passive TLD badges do not provide a direct on-body digital dose display.
Reader selection therefore needs more than a mechanical fit check: review detector material, heating conditions, element positions, identification, software and calibration arrangements for the proposed configuration.
A clear way to request a complete set
Use this format: “Please quote [quantity] complete sets, each containing [card configuration and detector material] plus [holder model], for use with [reader manufacturer and exact model]. List any required carriers and software separately.”
Compatibility should be confirmed for the specific detector, card, holder and reader configuration.